Model
|
W7-4000
|
W7-5000
|
W7- 6000
|
|
Output
|
Continuous output power
|
4000W
|
5000W
|
6000W
|
|
Surge ratings(20s)
|
12000W
|
15000W
|
18000W
|
|
Stared
|
4HP
|
5HP
|
6HP
|
|
Output wave form
|
Pure Sine wave/Same as input(Bypass mode)
|
|
Nominal efficiency
|
>88%(Peak)
|
|
Efficiency on line transfer mode
|
>95%
|
|
Power Factor
|
0.9-1.0
|
|
Nominal Output Voltage
|
220-230-240Vac
|
|
Output Voltage Regulation
|
±10% RMS
|
|
Output Frequency
|
50Hz ± 0.3Hz
|
|
Short Circuit Protection
|
Yes, Current Limit Function (Fault after 1sec)
|
|
Typical transfer Time
|
10ms(Max)
|
|
THD
|
< 10%
|
|
DC Input
|
Nominal Input Voltage
|
12.0Vdc
|
|
( *2 for 24Vdc, *4 for 48Vdc)
|
|
Minimum Start Voltage
|
10.0Vdc
|
|
Low Battery Alarm
|
10.5Vdc / 11.0Vdc
|
|
Low Battery Trip
|
10.0Vdc / 10.5Vdc
|
|
High Voltage Alarm & Fault
|
16.0Vdc
|
|
High DC Input Recovery
|
15.5Vdc
|
|
Low Battery voltage recover
|
13.0Vdc
|
|
Idle Consumption-Search Mode
|
< 25 W when Power Saver On
|
|
Charger
|
Input Voltage Range
|
Wide: 90~135VAC / 164~243VAC;
Narrow: 100~135VAC / 194~243VAC;
|
|
Output Voltage
|
Depends on battery type
|
|
Charger Breaker Rating
|
20A
|
30A
|
30A
|
|
Max Charge Rate
|
35A / 70-90A Max (Charger Current Control)
|
|
Over Charge Protection Shutdown
|
15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc)
|
|
Charger curve(4 stage constant current)
4 step digital controlled progressive charge
|
Battery types ( *2 for 24Vdc, *4 for 48Vdc)
|
|
Battery type
|
Fast Vdc
|
|
Gel U.S.A
|
13.7
|
|
A.G.M 1
|
13.4
|
|
A.G.M 2
|
13.7
|
|
Sealed Lead Acid
|
13.6
|
|
Gel Euro
|
13.8
|
|
Open Lead Acid
|
13.3
|
|
Calcium
|
13.6
|
|
De-sulphation
|
15.5 for 4hrs
|
|
Remote Control
|
Yes. Optional
|
|
Bypass & Protection
|
Input Voltage Waveform
|
Sine wave (Grid or Generator)
|
|
Nominal Voltage
|
120Vac
|
230Vac
|
|
Low Voltage Trip
|
80V/90V±4%
|
184V/154V±4%
|
|
Low Voltage re engage
|
90V/100V±4%
|
194V/164V±4%
|
|
High Voltage Trip
|
140V±4%
|
253V±4%
|
|
High Voltage re engage
|
135V±4%
|
243V±4%
|
|
Max Input AC Voltage
|
150VAC
|
270VAC
|
|
Nominal Input Frequency
|
50Hz or 60Hz (Auto detect)
|
|
Low Freq Trip
|
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
|
|
High Freq Trip
|
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
|
|
Overload protection
|
Circuit breaker
|
|
Output Short circuit protection
|
Circuit breaker
|
|
Bypass breaker rating
|
30A
|
40A
|
40A
|
|
Transfer switch rating
|
30amp for UL & TUV
|
|
Max bypass current
|
30amp
|
|
Mechanical Specification
|
Mounting
|
Wall mount
|
|
Inverter Dimensions(L*W*H)
|
598*218*179mm
|
598*218*179mm
|
|
Inverter Weight
|
35KG
|
45KG
|
45KG
|
|
Shipping Dimensions(L*W*H)
|
740*315*300mm
|
740*315*300mm
|
|
Shipping Weight
|
37KG
|
47KG
|
47KG
|
|
Display
|
Status LEDs / Status LEDs+LCD
|
|
Standard Warranty
|
1 Year
|
|
Specification canbe adjustable as to customer requirements.Any change of product specification without notice.
|